• Manufacturer Supplies Concrete Surface Strain Gauge
  • Manufacturer Supplies Concrete Surface Strain Gauge
  • Manufacturer Supplies Concrete Surface Strain Gauge
  • Manufacturer Supplies Concrete Surface Strain Gauge
  • Manufacturer Supplies Concrete Surface Strain Gauge
  • Manufacturer Supplies Concrete Surface Strain Gauge

Manufacturer Supplies Concrete Surface Strain Gauge

Aplication: Measuring Instruments, Test Instruments
Strain Gauge Type: Foil Type
Grim Dim: 2.0mm*3.7mm
Backing Dim: 9.0mm*5.6mm
Measurement Object: Force
Test Methods: Indicator Method
Customization:

Contact Supplier

Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
BB-A
Transport Package
Strain Gauge Special Pacakge
Specification
C3
Trademark
QYE
Origin
China
HS Code
9031809090
Production Capacity
1000000

Product Description

BF350-3BB-A Tee Rosette Strain Gauge 

Dimensions of Strain Gauge:


Manufacturer Supplies Concrete Surface Strain Gauge

Name Rules:
Manufacturer Supplies Concrete Surface Strain Gauge

 

Specification of strain gauge:

MODEL

GRID DIM

BACKING DIM

CREEP

L (mm)

W (mm)

L (mm)

W (mm)

BF350-3BB-A

3.0

3.0

6.8

7.6

 

ZF1000-3BB-A

3.0

3.0

6.8

7.6

If a strip of conductive metal is stretched, it will become skinnier and longer, both changes resulting in an increase of electrical resistance end-to-end. Conversely, if a strip of conductive metal is placed under compressive force (without buckling), it will broaden and shorten. If these stresses are kept within the elastic limit of the metal strip (so that the strip does not permanently deform), the strip can be used as a measuring element for physical force, the amount of applied force inferred from measuring its resistance.

Such a device is called a strain gauge. Strain gauges are frequently used in mechanical engineering research and development to measure the stresses generated by machinery. Aircraft component testing is one area of application, tiny strain-gauge strips glued to structural members, linkages, and any other critical component of an airframe to measure stress. Most strain gauges are smaller than a postage stamp.

A strain gauge's conductors are very thin: if made of round wire, about 1/1000 inch in diameter. Alternatively, strain gauge conductors may be thin strips of metallic film deposited on a nonconducting substrate material called the carrier. The latter form of strain gauge is represented in the previous illustration. The name "bonded gauge" is given to strain gauges that are glued to a larger structure under stress (called the test specimen). The task of bonding strain gauges to test specimens may appear to be very simple, but it is not. "Gauging" is a craft in its own right, absolutely essential for obtaining accurate, stable strain measurements. It is also possible to use an unmounted gauge wire stretched between two mechanical points to measure tension, but this technique has its limitations.

Typical strain gauge resistances range from 30 Ω to 3 kΩ (unstressed). This resistance may change only a fraction of a percent for the full force range of the gauge, given the limitations imposed by the elastic limits of the gauge material and of the test specimen. Forces great enough to induce greater resistance changes would permanently deform the test specimen and/or the gauge conductors themselves, thus ruining the gauge as a measurement device. Thus, in order to use the strain gauge as a practical instrument, we must measure extremely small changes in resistance with high accuracy.

Such demanding precision calls for a bridge measurement circuit. Unlike the Wheatstone bridge shown in the last chapter using a null-balance detector and a human operator to maintain a state of balance, a strain gauge bridge circuit indicates measured strain by the degree of imbalance, and uses a precision voltmeter in the center of the bridge to provide an accurate measurement of that imbalance:

 
 

Typically, the rheostat arm of the bridge (R2 in the diagram) is set at a value equal to the strain gauge resistance with no force applied. The two ratio arms of the bridge (R1 and R3) are set equal to each other. Thus, with no force applied to the strain gauge, the bridge will be symmetrically balanced and the voltmeter will indicate zero volts, representing zero force on the strain gauge. As the strain gauge is either compressed or tensed, its resistance will decrease or increase, respectively, thus unbalancing the bridge and producing an indication at the voltmeter. This arrangement, with a single element of the bridge changing resistance in response to the measured variable (mechanical force), is known as a quarter-bridge circuit.

As the distance between the strain gauge and the three other resistances in the bridge circuit may be substantial, wire resistance has a significant impact on the operation of the circuit. To illustrate the effects of wire resistance, I'll show the same schematic diagram, but add two resistor symbols in series with the strain gauge to represent the wires:

 
 

The strain gauge's resistance (Rgauge) is not the only resistance being measured: the wire resistances Rwire1 and Rwire2, being in series with Rgauge, also contribute to the resistance of the lower half of the rheostat arm of the bridge, and consequently contribute to the voltmeter's indication. This, of course, will be falsely interpreted by the meter as physical strain on the gauge.

While this effect cannot be completely eliminated in this configuration, it can be minimized with the addition of a third wire, connecting the right side of the voltmeter directly to the upper wire of the strain gauge:

 
 

Because the third wire carries practically no current (due to the voltmeter's extremely high internal resistance), its resistance will not drop any substantial amount of voltage. Notice how the resistance of the top wire (Rwire1) has been "bypassed" now that the voltmeter connects directly to the top terminal of the strain gauge, leaving only the lower wire's resistance (Rwire2) to contribute any stray resistance in series with the gauge. Not a perfect solution, of course, but twice as good as the last circuit!

There is a way, however, to reduce wire resistance error far beyond the method just described, and also help mitigate another kind of measurement error due to temperature. An unfortunate characteristic of strain gauges is that of resistance change with changes in temperature. This is a property common to all conductors, some more than others. Thus, our quarter-bridge circuit as shown (either with two or with three wires connecting the gauge to the bridge) works as a thermometer just as well as it does a strain indicator. If all we want to do is measure strain, this is not good. We can transcend this problem, however, by using a "dummy" strain gauge in place of R2, so that both elements of the rheostat arm will change resistance in the same proportion when temperature changes, thus canceling the effects of temperature change:

 
 

Resistors R1 and R3 are of equal resistance value, and the strain gauges are identical to one another. With no applied force, the bridge should be in a perfectly balanced condition and the voltmeter should register 0 volts. Both gauges are bonded to the same test specimen, but only one is placed in a position and orientation so as to be exposed to physical strain (the active gauge). The other gauge is isolated from all mechanical stress, and acts merely as a temperature compensation device (the "dummy" gauge). If the temperature changes, both gauge resistances will change by the same percentage, and the bridge's state of balance will remain unaffected. Only a differential resistance (difference of resistance between the two strain gauges) produced by physical force on the test specimen can alter the balance of the bridge.

Wire resistance doesn't impact the accuracy of the circuit as much as before, because the wires connecting both strain gauges to the bridge are approximately equal length. Therefore, the upper and lower sections of the bridge's rheostat arm contain approximately the same amount of stray resistance, and their effects tend to cancel:

 
 

Even though there are now two strain gauges in the bridge circuit, only one is responsive to mechanical strain, and thus we would still refer to this arrangement as a quarter-bridge. However, if we were to take the upper strain gauge and position it so that it is exposed to the opposite force as the lower gauge (i.e. when the upper gauge is compressed, the lower gauge will be stretched, and vice versa), we will have both gauges responding to strain, and the bridge will be more responsive to applied force. This utilization is known as a half-bridge. Since both strain gauges will either increase or decrease resistance by the same proportion in response to changes in temperature, the effects of temperature change remain canceled and the circuit will suffer minimal temperature-induced measurement error:
 
 

An example of how a pair of strain gauges may be bonded to a test specimen so as to yield this effect is illustrated here:
Manufacturer Supplies Concrete Surface Strain Gauge
 

With no force applied to the test specimen, both strain gauges have equal resistance and the bridge circuit is balanced. However, when a downward force is applied to the free end of the specimen, it will bend downward, stretching gauge #1 and compressing gauge #2 at the same time:
Manufacturer Supplies Concrete Surface Strain Gauge
 

In applications where such complementary pairs of strain gauges can be bonded to the test specimen, it may be advantageous to make all four elements of the bridge "active" for even greater sensitivity. This is called a full-bridge circuit:


Both half-bridge and full-bridge configurations grant greater sensitivity over the quarter-bridge circuit, but often it is not possible to bond complementary pairs of strain gauges to the test specimen. Thus, the quarter-bridge circuit is frequently used in strain measurement systems.

When possible, the full-bridge configuration is the best to use. This is true not only because it is more sensitive than the others, but because it is linear while the others are not. Quarter-bridge and half-bridge circuits provide an output (imbalance) signal that is only approximately proportional to applied strain gauge force. Linearity, or proportionality, of these bridge circuits is best when the amount of resistance change due to applied force is very small compared to the nominal resistance of the gauge(s). With a full-bridge, however, the output voltage is directly proportional to applied force, with no approximation (provided that the change in resistance caused by the applied force is equal for all four strain gauges!).

Unlike the Wheatstone and Kelvin bridges, which provide measurement at a condition of perfect balance and therefore function irrespective of source voltage, the amount of source (or "excitation") voltage matters in an unbalanced bridge like this. Therefore, strain gauge bridges are rated in millivolts of imbalance produced per volt of excitation, per unit measure of force. A typical example for a strain gauge of the type used for measuring force in industrial environments is 15 mV/V at 1000 pounds. That is, at exactly 1000 pounds applied force (either compressive or tensile), the bridge will be unbalanced by 15 millivolts for every volt of excitation voltage. Again, such a figure is precise if the bridge circuit is full-active (four active strain gauges, one in each arm of the bridge), but only approximate for half-bridge and quarter-bridge arrangements.

Strain gauges may be purchased as complete units, with both strain gauge elements and bridge resistors in one housing, sealed and encapsulated for protection from the elements, and equipped with mechanical fastening points for attachment to a machine or structure. Such a package is typically called a load cell.

Like many of the other topics addressed in this chapter, strain gauge systems can become quite complex, and a full dissertation on strain gauges would be beyond the scope of this book.

 
Our Services

 

1. OEM/ODM Services:

Our company provides OEM/ODM services and Customized products services. 

With know-how technique and mass production capability, we are able to provide the specified sensing solution according to customer's application. 

What's your requirement? 

2. Quality Quarantee

We quarantee product quality for one-year starting from the date of delivery. 

 

Company Information

  Marketing under Our Brand "QYE"
Hanzhong Quan Yuan Electronic Co. Ltd is a professional high-tech enterprise that is committed to the research, development, design, manufacture and sale of load cells, high precision resistance strain gauges and pressure transmitters under the QuanYuan brand. They can be applied in the traditional force measurement field and are also widely used in the industrial automation production lines and metallurgical industry.

Meeting CE, RoHS and EX Requirements
As an ISO 9001:2008-certified company,all our electronic products have good performance and high quality because all products must be tested several times and they must undergo strict inspections before being dispatched from the factory. As a result, our load cells have passed CE and RoHS requirements and pressure transmitters have passed CE and EX standards.

Service Concept: Customer Satisfaction is Our Everlasting Pursuit
With several years' experience in manufacturing and selling load cells, strain gauges and pressure transmitters, we always adhere to our service concept of "customer satisfaction is our everlasting pursuit" and have built a professional team in sensor field to provide customers with first-class products, first-class services, first-class reputation and first-class principles.

Exporting to over 30 Countries Worldwide
With high quality and good service, our products have been exported to over 30 countries, which include the US as well as those in Europe, Southeast Asia, the Middle East and South America.

 

FAQ

 

1. What is the MOQ?

For different product,the MOQ is different.But we can supply you samples.

2:How long will you give me the reply?
we will contact you in 12 hours as soon as we can.

3.How about the price?

As we believe the quality is the most important,we will provide the best quality product with reasonable price.

4:Could I visit your factory?
Of course,if you need we will help you to visit our factory.

5:If I have paid,when will you help me to produce?
When we have received the money in our account,we will give you the receipt and arrange to produce immediately.

6. What is lead time?  

If we have it in stock, we can ship it to you within about 3-5 working days. 

If we don't have it in stock, the lead time will be 10-30 days. 
If the product is urgent,please tell us and we will try our best to satisfy you.

7. What is the payment terms? 

All T/T, Western Union, L/C, Escrow,paypal  are acceptable. 

8. What is the express delivery? 

DHL, Fedex, TNT ,EMS, UPS etc. 

If you order large quantity products,the most economic shipping way will be by sea or by air transport. 

9. What is the quality guarantee? 

Quality guarantee:  12 months. 

If the product has quality problem within 12 months, please return it to us, we will repair it; if we can't repair it successfully, we will give you a new one; but the man-made damage, improper operation and force majeure will be excepted. 

And you will pay the shipping cost of returning to us, we will pay the shipping cost to you.

10. Is there any after-sale service? 

 After you receive our product, if you have any questions or need any assistance, we can provide you the after-sale service by e-mail,skype,trade manager,telephone and QQ etc. 

Send your message to this supplier

*From:
*To:
avatar Miss Teresa
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now