Basic Info.

Model NO.
QH-C5
Material
Alloy Steel
IP Rating
IP65
Certification
CE
Customized
Customized
Capacity
5kg to 50kg
Accuracy
0.1%Fs
Signal Output
1.0mv/V
Recommended Excitation
6~12VDC
Application
Body Scale, Personnel Scale, Kitchen Scale
Transport Package
Standard Exporting Inner Box and Outer Carton
Specification
CE, RoHS, ISO
Trademark
QYE
Origin
Shaanxi, China
HS Code
902690000
Production Capacity
100000PCS/Month

Product Description



                                                   
QH-C5 micro load cells are available in the capacity from 5kg to 50kg.
Alloy steel construction.  
Silicon adhesive, hermetically sealed, anti-oil, anti-corrosion and suitable for a variety of environment.
Integral structure and easy installation.
Suitable for hand scales, kitchen scales, postal scales, fishing scales, baby body scales and other micro electronic weighting systems.

Features:

Capacity:5kg to 50kg.
Defend grade: IP65
Tension and/or compression loading.
Reliable performance, integral structure and easy installation.

Technical Specifications:
 
SPECIFICATIONS UNIT RESULTS
Capacity Kg 5,10,15,20,25,30,50
Rated Output mV/V 1.0±0.15
Combined Error %FS ≤±0.3
Non-linearity %FS ≤±0.1
Hysteresis %FS ≤±0.2
Repeatability %FS ≤±0.2
Creep(5min) %FS ≤±0.1
Temp. Effect on SPAN %FS/10 oC ≤±0.2
Temp. Effect on ZERO %FS/10 oC ≤±0.2
Input Resistance Ω 1000±10
Output Resistance Ω 500±10
Recommended Excitation V 6~12
Maximum Excitation V 15
Insulation Resistance ≥5000
Compensated Temp. Range oC -10~+40
Operating Temp. Range oC -20~+60
Safe Overload %FS 120
Ultimate Overload %FS 150
Wiring Code excitation: Red  signal(+): Black
signal(-): White
Cable φ0.8×350mm


Applied in body Scale 
Body Weight Scale Load Cells with 3 Wires
Body Weight Scale Load Cells with 3 Wires
Body Weight Scale Load Cells with 3 Wires
Body Weight Scale Load Cells with 3 Wires
Body Weight Scale Load Cells with 3 Wires


1. What is the MOQ?
 If we don't have it in stock, the MOQ is 5 pcs 
If we have it in stock, we can ship you even 1 pc as sample. 
 
2. What is lead time? 
If we have it in stock, we can ship it to you within about 7 working days. 
If we don't have it in stock, the lead time will be 30-45 days. 
 
3. What is the payment terms? 
T/T, Western Union,   is acceptable. 
 
4. What is the express delivery? 
DHL, Fedex, TNT ,EMS, UPS etc. 
We will choose the safe and cheapest way for you to reduce your cost. 
Economic shipping way: by sea, by air transport 
If you place mass order with us, the shipping way of by sea or by air transport will be ideal choice. 
 
5. What is the quality guarantee? 
Quality guarantee:  12 months. 
If the product has quality problem within 12 months, please return it to us, we will repair it; if we can't repair it successfully, we will give you a new one; but the man-made damage, improper operation and force majeure will be excepted. 
And you will pay the shipping cost of returning to us, we will pay the shipping cost to you.
 
6. Is there any after-sale service? 
 After you receive our product, if you have any questions or need any assistance, we can provide you the after-sale service by e-mail,skype,trade manager,telephone
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now