• Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
  • Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
  • Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
  • Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
  • Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
  • Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA

Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA

Type: Load Cell Signal Amplifier
Used For: Load Cell
Tube Type: Transistor Amplifier
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA pictures & photos
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
US $30-45 / Piece
Min. Order: 2 Pieces
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
QA105
Function
Post Amplifier
Sound Channel
Signal Amplifier
Output Number
1
Voltage
AC 220V
Element Number
Push-Pull Amplifier
Conductive Mode
D
Theory
Resistance Sensor
Aplication
Load Cell
Linearity
0.02%Fs
Input Signal
0~2mv/V
Transport Package
Inner Side Plastic Bags, Outside Carton Box
Specification
C2
Trademark
QYE
Origin
Ce
HS Code
8423900000
Production Capacity
10000pieces/Month

Packaging & Delivery

Package Size
15.00cm * 12.00cm * 5.00cm
Package Gross Weight
0.380kg

Product Description

Load Cell Sensor Amplifier Transmitter strain gauge transducer 0-5V 0-10V 4-20MA 
Feature

1. Using full-blown lines and reliable device for amplifying and transmitting of the resistance strain
type weighing transducer,
outputting the signal: 0~10V ,(0~5V) or 4~20mA, connecting with PC or PLC to consist measuring control system;
2. Input signal: 0~2mv/v;
3. Output signal: 105 outputting 0~10V (0~5V), 106 outputting 4~20mA;
4.Supply power: DC24V(min18v,max36v);
5.Dimensions(mm):100×68×55;
6. Linearity: 0.02%FS.
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
Technique Datas:

Linearity

0.02%FS

input signal range

6~30mA

Zero range

0~60%

Adjustable full-scale range

6~30mV

Sensor excitation power

9 ~ 12V adjustable output voltage, current limiting with short circuit protection ≤200mA

Zero hysteresis range

Voltage signal: 0 ~ 5V

Current signal: 0 ~ 20mA (load resistance ≤500Ω)

Excitation power supply

temperature stability

25ppm/ºC

Sensor excitation power

9 ~ 12V adjustable output voltage, current ≤200mA, with short circuit current limit protection

Power supply

AC220±22V,50HZA or DC24±1V or DC12±1V

Power consumption About

5VA

Working temperature

-10~50ºC

temperature

≤80%RH

Wiring Box

160 × 152 × 67mm (height × width × thickness)

(Not including connectors)

92(L)×63(W)×32(H)mm,48(L)×33(W)×17(H)mm




Electrical connection

1. QA-105/106 are all using inputting/outputting joints, connecting separately the input signal of transducer and the output signal of module.

2. The request for signal cable: transmitter use plastic waterproof joint,;

The request for Cable diameter:6±0.3(mm).
3. The connection type of the transducer signal inputting terminals corresponding to connecting line terminals:
V+: Excitation +;
GND: Excitation -;
IN+: output signal +;
IN-: output signal -.
4. The connection type of the module signal inputting terminals
corresponding to connecting line terminals:
OUT: the terminal of transmitter signal outputting;
DC: 24V amplifying/Excitation+;
GND: amplifying / Excitation-ground.


Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA

The adjusting and the ordering instrument of the product:

1.The correct connecting the transducer with the supply power, after 10 minutes powering on, when the transducer is out off load ,to adjust the potentiometer which shows "Z" making the outputting for 0Vor 4mA; Adding to the standard load, adjusting the potentiometer which shows "S" making the outputting for 10V(5V) or 20mA.
2. The transducer power supply of 105 and 106 amplification transmitter:
Standard: 15V, Delicate: 10V.
3. Please explain the sensitivity and the output resistance of the
transducer, when ordering.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA pictures & photos
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
US $30-45 / Piece
Min. Order: 2 Pieces
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Management System Certification
GB/T 23001-2017