Bf-350-Ca Tri-Element Rosette Strain Gauge

Product Details
Customization: Available
Resistance: 0.5%, 0.1%
Backing Material: Modified Phenolic
Manufacturer/Factory & Trading Company
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
GB/T 23001-2017
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
  • Bf-350-Ca Tri-Element Rosette Strain Gauge
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
BF-CA strain gauge flower
Output
Analog Sensor
Theory
Resistance
Grid Material
Constantant Karma
Transport Package
Carton
Trademark
QYE
Origin
China
HS Code
9031809090
Production Capacity
30000/Year

Product Description

  
Product Description

 

Rosette strain gauge is also called strain flower. Strain flower is the use of two or more strain gauges, closely arranged to measure the strain members in different directions. A single strain gauge can only measure the strain in a single direction. The strain flower can measure the strain on the measured surface more accurately by using multiple strain gauges to measure the strain in multiple directions. The 90 degree Angle vertical strain flower is equivalent to two AA strain gauges overlapping 90 degrees.
Bf-350-Ca Tri-Element Rosette Strain Gauge
Product Parameters

PRODUCT MODEL TABLE (Unit: mm)

MODEL GRID DIM BACKING DIM Distance to Center mm
L (mm) W (mm) L (mm) W (mm)
BF350-3BC  5.3 5.3 8.0 8.0  
ZF1000-3CA  6.3 6.5 10.3 10.3
TECH SUPPORTBf-350-Ca Tri-Element Rosette Strain GaugeTypes to select We should select strain gauge according to the tested purpose, the materials and precision demands of the tested goods. For example, the sense organ of the load cell, then it need to select the Foil strain gauge which is small P and θ; If the sensitivity of the load cell needs to be large, then we should select Semiconductor strain gauge; we should select Foil strain gauge if we test the dynamic weighing.
 The fundus materials of the Sensitive Grids How to select the best and suitable Sensitive Grids or fundus materials? First, we should according to the environment, temperature, tested time and the ultimate straining, then we also need to consider the precision demand of the strain gauge, For example: In -30~+80 , you should choose ºC CuNi, NiCrFe or Phenolic strain gauge; And in 80~150 , the ºC n use Polyimide strain gauge is better. The resistance of strain gauge We consider and select the resistance of strain gauge according to the demands which the test equipment require to the resistance and sensitivity of strain gauge etc. For example, in the stress test, we usually use 120ohm train gauge to match the equipment; To the load cell, we use high resistance (350ohm, 500ohm, 1000 ohm even larger etc.) to improve its stability and sensitivity, sometimes we also consider the performance and the values and the function, we use high resistance strain gauge.
 Dimension of strain gauge We decide the dimension of strain gauge according to the materials, stress and the sticked area.
For example, we use longer grids strain gauge if the stress is proportional or the changing is small, and it allow to stick on a large area, in this condition, we suggest to use 3~6mm's grids; but we use the grids length≤1mm, if the stress is collected in area or the sticked area is small. The long grids strain gauge is good for stick, connection and good cool function; it also can improve the performance of the strain gauge. The dimension of the strain gauge is smaller, the demands of strict quality are higher, and the cool function is weaker, so on conditions of insure the precision and have enough sticked area, it is better to use long grids strain gauge.
Bf-350-Ca Tri-Element Rosette Strain GaugeThe configuration of the Sensitive Grids We select the configuration of the Sensitive Grids according to the stress and other demands. Like when the main stress is unknown or shear strain, then we can select multi-axes strain gauge, we use these strain gauge which Triaxial angle are 45°, 60° or 120° for the first situation; And use Triaxial angle is 45° for another situation. If we test the know stress strain, then we can select Uniaxial strain gauge; the circle multi-axes strain gauge is used in Pressure sensor.
Temp. Self-compensation and Elastic Modulus self-compensation We should select different Temp. Self-compensation or Elastic Modulus self-compensation strain gauge according to its materials, working Temp. and the precision. Like some common steel or spring steel, then use Temp. Self-compensation strain gauge with the 11×10/ expansion coefficient; And to ºC the Aluminum alloy, then use strain gauge with 23×10/ expansion coefficient. ºC
Creep Grade The user should select the matching Creep Grade according to the configuration, capacity and Elastomer of the load cell. First time we can select one or two kind of different Creep Grade's strain gauge to test, and according to the last test data, and then select the best Creep Grade.